<?xml version="1.0" encoding="utf-8"?>
<?xml-stylesheet type="text/css" href="http://www.obd-scanner.com/includes/templates/template_default/css/rss.css" media="screen"?>
<!-- generator="Zen-Cart RSS Feed/"v 2.1.4 14.02.2008 15:26 -->
<rss version="2.0" 
xmlns:g="http://base.google.com/ns/1.0"
xmlns:c="http://base.google.com/cns/1.0"
xmlns:atom="http://www.w3.org/2005/Atom">
  <channel>
    <title>obd-scanner.com : RSS Product Feed :: Digital Clamp-On Meter 9702</title>
    <link>http://www.obd-scanner.com/</link>
    <description></description>
    <atom:link href="http://www.obd-scanner.com/" rel="self" type="application/rss+xml" />
    <language>DE</language>
    <copyright>Copyright (c) 2026 Shen Zhen ZvgeInfo Technology Co., Ltd</copyright>
    <managingEditor>samsondai168@gmail.com (Shen Zhen ZvgeInfo Technology Co., Ltd)</managingEditor>
    <webMaster>samsondai168@gmail.com (Shen Zhen ZvgeInfo Technology Co., Ltd)</webMaster>
    <lastBuildDate>Wed, 15 Jan 2014 09:16:59 +0800</lastBuildDate>
    <generator>Zen-Cart v. v 2.1.4 14.02.2008 15:26 RSS 2.0 Feed</generator>
    <ttl>1440</ttl>
    <item>
      <title>Digital Clamp-On Meter 9702</title>
      <link>http://www.obd-scanner.com/digital-clampon-meter-9702-p-779.html</link>
      <comments>http://www.obd-scanner.com/index.php?main_page=product_reviews&amp;products_id=779</comments>
      <description><![CDATA[ <a href="http://www.obd-scanner.com/digital-clampon-meter-9702-p-779.html"><img src="http://www.obd-scanner.com/images/l/201401/13897766970.jpg" alt="Digital Clamp-On Meter 9702" title=" Digital Clamp-On Meter 9702 " width="100" height="100" style="float: left; margin: 0px 8px 8px 0px;" /></a><p><strong>Digital Clamp-On Meter 9702</strong><br /><br /><strong>Description</strong><br /><br /><strong>DC Current Measurement</strong><br /><span>Range: 3, 20 A, 40A, 200A</span><br /><span>Basic accuracy: (2.5% + 3d)</span><br /><span>Resolution: 10mA</span><br /><strong>Note: Before measuring DC current test to ensure that no form T connected with the instrument.</strong><br /><br /><strong>AC Current Measurement</strong><br /><span>Range: 20 A, 40A, 200A</span><br /><span>Basic accuracy: (3.0% + 4d)</span><br /><span>The maximum resolution: 10mA</span><br /><strong>Note:</strong><span> </span><strong>AC current measurement before the test to ensure that the table T does not connect with the instrument.</strong><br /><br /><strong>DC Voltage Measurement</strong><br /><span>Range: 5, 400 mV, 4V, 40V, 400V, 600V</span><br /><span>Basic accuracy: (0.8% + 2d)</span><br /><span>Resolution: 0.1 mV</span><br /><br /><strong>AC Voltage Measurement</strong><br /><span>Range: 4, 4V, 40V, 400V, 600V</span><br /><span>Basic accuracy: (1.5% + 3d)</span><br /><span>Resolution: 0.1 mV</span><br /><br /><strong>Resistance Measurement</strong><br /><span>The largest measuring resistance of 40 M &Omega;</span><br /><span>Basic accuracy: (1.2% + 4d)</span><br /><span>Resolution: 0.01 M &Omega;</span><br /><br /><strong>Capacitance Measurement</strong><br /><span>The largest measuring capacitance to 200.0 uF</span><br /><span>Basic accuracy: (3.5% + 5d)</span><br /><span>Resolution: 0.1 &mu; F</span><br /><br /><strong>Frequency Measurement</strong><br /><span>The largest measuring frequency of 9.999 MHz, duty cycle of 0.1% to 99.9%</span><br /><span>Basic accuracy: (0.8% + 3d)</span><br /><span>Resolution: 0.01 Hz</span><br /><span>Diodes and short-circuit test</span><br /><span>Diode test, the test current: 0.3 mA typical, open circuit voltage: 1.5 V DC typical</span><br /><span>Short-circuit test, <30 &Omega; at the beep, the current test <0.3 mA</span><br /><br /><strong>Numerical Maintain Functional</strong><br /><span>Press the button to maintain the numerical value locked. When the numerical maintain functional activities in the state will be displayed on the screen reading and "HOLD". Numerical again press the button to maintain cancel this feature.</span><br /><span>Cleared function</span><br /><span>Automatically cleared keys to DC current measurement, 400 mV DC voltage measurement, 4 V AC voltage measurement, capacitance measurement.</span><br /><br /><strong>Specifications<br />DC</strong><br /><span>Measuring range Resolution Accuracy rate (% of reading)</span><br /><span>40A 0-20A 10mA 3.0%+6dgts</span><br /><span>20A-40A 10mA 5.0%+6dgts</span><br /><span>200A 100mA 3.5%+3dgts</span><br /><br /><strong>Current Exchange: </strong><br /><span>Measuring range Resolution Accuracy rate (% of reading)</span><br /><span>50~60Hz 60~100Hz 100~400Hz 400~1000Hz</span><br /><span>0-20A 10mA 3%+4dgts 3%+7dgts 3%+10dgts 3%+30dgts</span><br /><span>20-40A 10mA 5%+4dgts 5%+7dgts 5%+10dgts 5%+30dgts</span><br /><span>200A 100mA 3.5%+4dgts 3.5%+7dgts 3.5%+10dgts 3.5%+30dgts</span><br /><br /><strong>DC Voltage (Automatic Measurement) </strong><br /><span>Measuring range Resolution Accuracy rate (% of reading)</span><br /><span>400.0mV 0.1mV 0.8% of rdg+2 dgts</span><br /><span>4.000V 1mV 1.0% of rdg+2 dgts</span><br /><span>40.00V 10mV</span><br /><span>400.0V 100mV</span><br /><span>600V 1V 1.5% of rdg+2 dgts</span><br /><br /><strong>AC Voltage (Automatic Measurement) </strong><br /><span>Measuring range Resolution Accuracy rate (% of reading)</span><br /><span>4.000V 1mV 1.5% of rdg+3 dgts</span><br /><span>40.00V 10mV</span><br /><span>400.0V 100mV</span><br /><span>600V 1V 2.0% of rdg+4 dgts</span><br /><span>Resistance (automatic measurement)</span><br /><span>Measuring range Resolution Accuracy rate (% of reading)</span><br /><span>Range Resolution Accuracy</span><br /><span>400.0&Omega; 0.1&Omega; 1.2% of rdg+4 dgts</span><br /><span>4.000k&Omega; 1&Omega; 1.2% of rdg+2 dgts</span><br /><span>40.00k&Omega; 10&Omega;</span><br /><span>400.0k&Omega; 100&Omega;</span><br /><span>4.000M&Omega; 1k&Omega;</span><br /><span>40.00M&Omega; 10k&Omega; 2.0% of rdg+3 dgts</span><br /><br /><strong>Capacitance (Automatic Measurement)</strong><br /><span>Measuring range Resolution Accuracy rate (% of reading)</span><br /><br /></p>
<p> </p>
<br /><br /><a href="http://www.obd-scanner.com/index.php?main_page=shopping_cart&products_id=779&action=buy_now" target="_blank"><img src="http://www.obd-scanner.com/includes/templates/template_default/buttons/german/button_buy_now.gif" alt="Jetzt kaufen" title=" Jetzt kaufen " width="71" height="16" /></a> ]]></description>
      <author>samsondai168@gmail.com (Shen Zhen ZvgeInfo Technology Co., Ltd)</author>
      <guid isPermaLink="true">http://www.obd-scanner.com/digital-clampon-meter-9702-p-779.html</guid>
      <pubDate>Wed, 15 Jan 2014 09:05:17 +0800</pubDate>
      <g:price>101.00</g:price>
      <g:currency>EUR</g:currency>
      <g:id>779</g:id>
      <g:weight>0.6</g:weight>
      <g:quantity>1111110</g:quantity>
      <g:model_number>AD16</g:model_number>
      <g:image_link>http://www.obd-scanner.com/images/s/201401/13897766970.jpg,s/201401/13897766971.jpg,s/201401/13897766972.jpg,s/201401/13897766983.jpg,s/201401/13897766984.jpg</g:image_link>
    </item>
  </channel>
</rss>
